3. Advanced Commands
50% corresponds to a zoom window in the middle of the window.
Command
Command [0]
\x21
Command [1]
\x83
Data
Data [0]...Data [3] = double word(= 4 bytes; see ch
apter "1. Serial communications Basics", "Data words", page 6) corresponding
to the actual Y position (100% = right border).
Data[4] = unsigned byte : represents the decimal part.
3.12.10 Window size, Increment
Description
This command increments the zoom factor of the active window (window which has the focus).
This is done by incrementing the size percentage, the rate of increment can also be specified.
Command
Command [0]
\x22
Command [1]
\x81
Data
Data [0] = byRepeat =1 byte to define the rate of increment
3.12.11 Window X position, Increment
Description
This command increments the X position of the zoom window.
This is done by incrementing the X position percentage, the rate of increment can also be specified
Command
Command [0]
\x22
Command [1]
\x82
Data
Data [0] = byRepeat =1 byte to define the rate of increment
3.12.12 Window Y position, Increment
Description
This command increments the Y position of the zoom window.
This is done by incrementing the Y position percentage, the rate of increment can also be specified
Command
Command [0]
\x22
Command [1]
\x83
Data
Data [0] = byRepeat =1 byte to define the rate of increment